solarwinds hybrid cloud observability network monitoring practice test
Hybrid Cloud Observability Network Monitoring
Last exam update: Nov 18 ,2025
Page 1 out of 11. Viewing questions 1-15 out of 151
Question 1
Which three of the following actions are native log entry actions? (Choose three.)
A.
add a tag to the log entry
B.
continue rule processing but do not save
C.
halt further rule processing for the log entry
D.
send an email notification
Answer:
A, B, C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 2
If a NetFlow collector service is showing a “down” status, which two of the following steps are possible troubleshooting options? (Choose two.)
A.
Confirm the database connection is up and server has free resources.
B.
Delete and re-add NetFlow collector service.
C.
Start or restart SolarWinds’ collector service.
D.
Start or restart SolarWinds’ NetFlow service from Orion service manager.
Answer:
A, D
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 3
What is the minimum amount of RAM required for setting up log collection in hybrid cloud observability?
A.
4 GB
B.
GB
C.
16 GB
D.
32 GB
Answer:
C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 4
A universal device poller (UDP) was created on the main polling engine to collect CPU temperature for routers polled by the main polling engine and switches polled by the additional polling engine. It is noted that statistics from the switches are missing. What is the likely cause of the missing statistics?
A.
routers are not monitored on the additional polling engine
B.
switches are not monitored in the additional polling engine
C.
UDPs are tied to polling engine on which they are hosted
D.
UDPs do not work with additional polling engines
Answer:
C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 5
A probe is to be built to test connections to Office 365 from two different locations. How would this be accomplished?
A.
Create a probe, duplicate it, and change the source agent to the agent in another location.
B.
Create both probes on hybrid cloud observability (HCO) server and designate each location.
C.
Create two probes and assign each to an agent in each location.
D.
Create two probes and assign each to an agent in one location.
Answer:
C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 6
Flow data is not generating from a device in the web console. Wireshark was used to confirm the flows are being sent from the device to the poller and not blocked by the firewall. Why is the data not showing in the web console?
A.
device is not monitored by hybrid cloud observability (HCO) features
B.
device is using IPv6 and HCO only supports IPv4
C.
missing source address field in flow configurations
D.
flow monitoring was not enabled as device type in web console settings
Answer:
C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 7
Which two of the following tasks must be accomplished to monitor servers and connections in a load-balancing environment? (Choose two.)
A.
add Cisco Nexus device in network device configuration manager
B.
add Cisco Nexus device in network health / performance monitoring
C.
enable CLI polling
D.
enable F5 iControl polling
Answer:
B, D
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 8
What is a possible result of decreasing the top talking optimization value?
A.
increased storage requirement
B.
reduced database performance
C.
reduced page load times
D.
slower reporting speed
Answer:
A
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 9
Which two of the following troubleshooting steps can be performed when a node is “up” and the data cannot be found in SolarWinds’ platform web console? (Choose two.)
A.
Add a remote site node and make sure the firewall rules are configured to allow SNMP traffic.
B.
Ping the device from the polling engine the device is assigned to using the command line.
C.
Verify hardware health sensors on the device provide both status and values.
D.
Wait ten minutes after a device is added to the console. Refresh the screen.
Answer:
B, D
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 10
Which tool can be used to display the physical layout of interfaces on graphical stencils?
A.
device studio
B.
device view
C.
NetPath
D.
network insight
Answer:
B
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 11
Which two of the following best practices are used when creating a universal device poller (UDP)? (Choose two.)
A.
Call SolarWinds support for object ID (OID) options.
B.
Consult vendor documentation for OID.
C.
Perform SNMPwalk to determine if OID exists.
D.
Run WBemtest to test communication to OID.
Answer:
B, C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 12
A poller is to be built that will add two values together to show a single value in the web console using the universal device poller (UDP) tool. How would this be accomplished?
A.
add both object IDs (OIDs) to the poller and combine values in a single value for the web console
B.
build a poller for each OID then use transform results to combine values from the two pollers
C.
UDP tool does not support more than one OID per poller, another OID is needed
D.
UDP tool does not support more than one OID per poller, another tool is needed
Answer:
B
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 13
Which two of the following flow sources are supported by hybrid cloud observability? (Choose two.)
A.
Cisco
B.
cFlow
C.
J-Flow
D.
NetStream
Answer:
A, C
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 14
Which two of the following statements explain creating alerts for NBAR2 applications? (Choose two.)
A.
Applications and NBAR2 applications in top applications are sorted by bits.
B.
Applications and NBAR2 applications in top applications are sorted by bytes.
C.
It is not possible to combine applications and NBAR2 applications.
D.
It is possible to combine applications and NBAR2 applications.
Answer:
B, D
User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
0/ 1000
Question 15
Which port allows log analysis in the SolarWinds platform to accept secure syslog messages?