An Implementation Engineer is performing a capacity consolidation on an X50R3.
Which command is needed for the engineer to determine whether the customer’s FlashArray
supports SAS Flash Modules?
C
Explanation:
This command reports every installed drive module, identifying SAS Flash Modules if present,
whereas the other commands do not enumerate individual drive types.
On a FlashArray//XR50R2/3 Fibre Channel (FC) array, what is the default type and placement of the
PCIe FC card?
B
Explanation:
On an X50R2/3 FC array, Pure ships each controller with a factory-installed dual-port 32 Gb Fibre
Channel card in the PCIe slot numbered 2, providing out-of-the-box SAN connectivity.
A data pack has been installed and the puredrive list command shows the drives in “unadmitted”
status. Which command should be used to complete the admission?
B
Explanation:
The puredrive admit command is used to complete the admission process for drives showing as
"unadmitted," integrating them fully into the FlashArray.
What is the redundancy of the FlashArray//XL PSUs?
B
Explanation:
FlashArray//XL power supply units (PSUs) are designed with 2+2 redundancy, meaning there are four
PSUs where any two can fail without impacting array operation.
Which PCIe slot supports 4-port FC cards on FlashArray//XL?
C
Explanation:
On FlashArray//XL, the PCIe slot 8 supports installation of 4-port Fibre Channel cards, allowing higher
port density for SAN connectivity.
A FlashArray//XR2/3 has an Ethernet mezzanine (EMEZZ), what are the interface names of the ports
on the mezzanine?
B
Explanation:
The Ethernet mezzanine on FlashArray//XR2/3 is assigned interfaces starting at ETH8 through ETH11,
reflecting the numbering scheme for additional Ethernet ports beyond the base interfaces.
What should an Implementation Engineer do when installing rails in a threaded-hole rack?
A
Explanation:
Positioning studs are used to align and secure the rails correctly in a threaded-hole rack, ensuring
proper installation and stability of the FlashArray.
Support requests a powercycle on a newly-installed FlashArray. What is the correct way to perform
this action?
C
Explanation:
The proper and safe method to power cycle a FlashArray is to run the purearray reboot command,
which gracefully restarts the system without risking data integrity or hardware issues.
Before leaving the site after an install, who is required to provide completion sign-off?
B
Explanation:
The customer’s completion sign-off is required to confirm that the installation meets their
expectations and requirements before the engineer leaves the site.
Prior to running the puresetup newarray command, which command should an Installation Engineer
run on a new install of an //XR4 array?
B
Explanation:
Running cobalt_check.py on a new //XR4 array verifies hardware and system readiness before
executing puresetup newarray, ensuring a smooth setup process.
A customer has a FlashArray X20R3 with 22/22 data packs in the chassis at 80% space usage and
wishes to swap one of the data packs for a 45TB pack. What step needs to be taken to facilitate this
consolidation?
B
Explanation:
Adding a DirectFlash Shelf with sufficient temporary extra capacity (63TB) allows data to be
evacuated from the smaller 22TB packs during the swap, enabling consolidation without reducing
array usage beforehand.
An Implementation Engineer is onsite to install a new DFM data pack (DP) to CH0.BAY10-CH0.BAY19
of a FlashArray.
After adding the drives to the chassis, which command should the Implementation Engineer run to
verify if the new DP is in a wide write group?
C
Explanation:
The puredrive list --pack command shows detailed information about the specified data pack,
including whether its drives are part of a wide write group.
What is the rack unit height of a FlashArray//XR2/3?
A
Explanation:
The FlashArray//XR2 and //XR3 models each occupy 3 rack units (RU) in height. This is specified in
the FlashArray//XR2 and //XR3 Site Planning Guide, which outlines the physical requirements for
rack space, clearance, and weight for these models.
An Implementation Engineer is beginning a controller upgrade. Which command should be run to
stop Purity?
C
Explanation:
The command pureadm stop --controller CT0 specifically stops Purity on the designated controller
(CT0), which is the correct step to safely begin a controller upgrade.
When transforming an array from SAS to NVMe with the Evergeen XFORM upgrade, when should a
swing shelf be installed?
B
Explanation:
A swing shelf is installed during the SAS to NVMe Evergreen XFORM upgrade only if the array lacks
enough free capacity to evacuate data packs, enabling safe data migration during transformation.