Huawei hc-621 practice test

HCNP-SSAM(SAN Storage Advanced Management)- ENU Exam


Question 1

About operational processes virtual snapshot storage array is correct.

  • A. Create a virtual snapshot --- > to create a resource pool --- > Activate virtual snapshot --- > virtual snapshot rollback
  • B. Create a virtual snapshot --- > Activate virtual snapshot --- > to create a resource pool --- > virtual snapshot rollback
  • C. Create a resource pool --- > Create a virtual snapshot --- > Activate virtual snapshot --- > virtual snapshot rollback
  • D. None of the above comments
Answer:

C

Discussions
0 / 600

Question 2

As follows using parity data redundancy protection raid levels are. (Choose two)

  • A. RAID1
  • B. RAID2
  • C. RAID 3
  • D. RAID 5
Answer:

C, D

Discussions
0 / 600

Question 3

In the storage array snapshot scenario common faults are there? (Choose three)

  • A. Failed to activate snapshot
  • B. Snapshot rollback fails
  • C. Virtual snapshots automatically stop
  • D. Deleting a snapshot fails
Answer:

A, B, C

Discussions
0 / 600

Question 4

Which of the following is a common host-side redundancy? (Choose three)

  • A. The controller cache mirroring
  • B. Dual database failover
  • C. OS system disk image
  • D. Network interface bindings
Answer:

B, C, D

Discussions
0 / 600

Question 5

How to check whether the physical status of the hard drive properly S5000 system?

  • A. showdisk-p
  • B. showsys
  • C. showrg
  • D. showlun
Answer:

A

Discussions
0 / 600

Question 6

Under FC SAN networking environment, a host LUN result in some loss of business interruption, this
failure scenario, the main reason may be? (Choose three)

  • A. RAID LUN resource failure
  • B. iSCSI host port physical link failure
  • C. Switch port exception (Down / Restart)
  • D. HBA card failure
Answer:

A, C, D

Discussions
0 / 600

Question 7

SCSI read during the interactive process, start to interact with the target startup process than writing
less and the target device, the main goal is the process of writing assignment needs to be cached.

  • A. True
  • B. False
Answer:

A

Discussions
0 / 600

Question 8

Because SAS is a serial SCSI, so the transfer rate is usually lower than parallel SCSI.

  • A. True
  • B. False
Answer:

B

Discussions
0 / 600

Question 9

For the S5000 and S2600 systems, DB configuration information is stored in the system, when the
record on safe electrical system controller reads the disk DB, if you have a DB is inconsistent with
other DB storage device into safe mode will not work properly, DB need to synchronize information

  • A. True
  • B. False
Answer:

A

Discussions
0 / 600

Question 10

With the same specifications, the number of hard drives in the RAID group established in reading and
writing in the same business, Raid10 random write performance and Raid5 random write
performance is roughly equal.

  • A. True
  • B. False
Answer:

B

Discussions
0 / 600
To page 2