HP hpe0-s60 practice test

Delta - HPE Compute Solutions

Last exam update: Nov 18 ,2025
Page 1 out of 6. Viewing questions 1-15 out of 79

Question 1

A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?

  • A. Brocade 32GB Fibre Channel Switch Module for HPE Synergy
  • B. HPE virtual Connect SE 32 Gb FC Module for Synergy
  • C. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy
  • D. HPE Synergy 12 Gb SAS Connection Module
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 2

Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast
broadcast and destination lookup failure (OLF) packets?

  • A. Pause flood protection
  • B. Loop protection
  • C. LLDP tagging
  • D. Storm control
Mark Question:
Answer:

D


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 3

Which statement about a new HPE SimpliVity deployment is true?

  • A. New HPE SimpliVity deployments give customer flexible choice of hypervisor
  • B. All new HPE SimpliVity models are based on AMD CPUs
  • C. All new HPE SimpliVity models support deduplication and compression
  • D. New HPE SimpliVity deployments are licensed per node not per physical socket
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 4

You configured a vVoI datastore using HPE Storage integration Pack for VMware vCenter.
Which storage object should you check using SSMC to verify whether vVol datastore is configured
property?

  • A. App Volume Set
  • B. Storage Container
  • C. Virtual Volume Set
  • D. virtual Volume
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 5

Which statement about login redistribution is true?

  • A. Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
  • B. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports
  • C. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
  • D. Login redistribution is used for login balancing when they are not distributed evenly over the FC links
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 6

Which statement about an HPE Oneview support dump is true?

  • A. Appliance support dump by default contains a logical enclosure support dump
  • B. Support dump is a binary file that can be opened only in a dedicated application
  • C. Support dump can be created if HPE Virtual Connect modules are installed in the frame
  • D. Preview support dump is available only when creating an appliance support dump
Mark Question:
Answer:

B


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 7

Refer to the exhibit.

Which statement about this logical interconnect group is true?

  • A. The master modules are located in the interconnect bays 2 and 5
  • B. For the given downlink speed, the maximum number of frames is reached
  • C. Both master modules are located in the same HPE S ynergy frame
  • D. To use interconnect bay set 3, all compute nodes must be half-height
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 8

An administrator tries to open iLO interlace from HPE OneView Instead of being automatically logged
in a login prompt displays
Where should you start the troubleshooting process?

  • A. At the iLO interface to verify whether the ILO Advanced license is properly applied
  • B. At HPE OneView Interface to verify whether the server is In the maintenance mode
  • C. At the iLO interface to verify whether the SSO certificate is removed from an iLO.
  • D. At HPE OneView Interface to verify whether the iLO processor is disabled
Mark Question:
Answer:

A


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 9

Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN
deployment leveraging HPE D3940 Storage Modules and SSD drives
The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options
Which statement about this request is true?

  • A. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
  • B. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
  • C. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
  • D. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
Mark Question:
Answer:

B


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 10

Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use
Distributed Switches and DRS cluster
You are preparing a proposal with the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- an appropriate number of the vSphere Standard licenses for each compute node
- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options
Which statement about this proposal is true?

  • A. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
  • B. vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features
  • C. 2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup
  • D. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.
Mark Question:
Answer:

B


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 11

Your customer has the following HPE Synergy setup
- 3 HPE Synergy 12000 Frames
- 4 HPE Virtual Connect SE 100 Gb F32 Modules
- 2 HPE Synergy 50 GO Interconnect Link Modules
- 36 HPE Synergy 480 Gen10 Plus compute modules
- 2 HPE Composer 2 modules
Which statement about this setup is true?

  • A. To use all compute nodes, the customer must create at least two logical enclosures
  • B. To manage all frames, the customer must buy two additional HPE Composer 2 modules
  • C. The customer must buy 36 HPE OneView Advanced licenses to manage compute modules
  • D. The customer can add one D3940 storage Module to each of the frames
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 12

HOTSPOT
An HPE Synergy customer needs to prevent a timeout and loss of communication during an external
switch firmware upgrade.
Click the parameter that the customer should configure within an uplink set to meet this
requirement

Mark Question:
Answer:


Explanation:

User Votes:
Discussions
vote your answer:
0 / 1000

Question 13

Which statement about HPE Superdome Flex 280 is true?

  • A. It supports 2 to 8 sockets in 2-socket increments.
  • B. it cannot be managed using HPE OneView.
  • C. It must be equipped with at least 768 GB of memory.
  • D. It can support up to two nPars with an external RMC.
Mark Question:
Answer:

C


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 14

You are troubleshooting an HPE OneView server profile that presents a critical state. The server
profile was configured with a Link Aggregation Group
What should you check to fix the issue?

  • A. if both FiexNICs are configured with the same speed
  • B. If the logical enclosure is built on at least three HPE Synergy frames
  • C. if both FiexNICs are connected to different networks
  • D. if the logical enclosure is configured with redundant master modules
Mark Question:
Answer:

A


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000

Question 15

Your customer experienced some problems caused by outdated HPE Superdome Flex firmware.
Which update method should they use to avoid these issues in the future?

  • A. HPE OneView method for I/O firmware update procedure
  • B. RMC CLI to update I/O and HPE Persistent Memory firmware
  • C. HPE OneView IT HPE Persistent Memory firmware must be updated.
  • D. HPE SUM if HPE Persistent Memory firmware must be updated
Mark Question:
Answer:

B


User Votes:
A
50%
B
50%
C
50%
D
50%
Discussions
vote your answer:
A
B
C
D
0 / 1000
To page 2